MITSUBISHI INTELLIGENT POWER MODULES PM50CTK060 FLAT-BASE TYPE INSULATED PACKAGE PM50CTK060 600V, 50A Current-sense 6kHz IGBT type inverter Built in IGBT gate drive circuit Built in Faule OC, SC, OT & UV protection Fault output 3.7kW class inverter application APPLICATION Air conditioner, mortor control OUTLINE DRAWING Dimensions in mm A * B: TERMINAL NAME 1. 2. 3. 4. 5. 6. 7. 8. 9. VUPC NC UP VUP1 VVPC NC VP VVP1 VWPC 10. 11. 12. 13. 14. 15. 16. 17. 18. NC WP VWP1 VNC VN1 NC UN VN WN 19. 20. 21. 22. 23. 24. 25. FO P NC N U V W 100.5 1 88.5 0.5 60.96 0.8 0.75 15 - 2.54 0.25 (13.77) 7.62 7.62 7.62 1234 5678 9 10 11 12 13 14 15 16 17 18 19 4 - R5 58.5 0.8 56.5 0.5 70 1 41 20 21 22 23 24 25 4 - 4.5 (13) 12.5 0.25 12.5 0.25 12.5 0.25 12.5 0.25 12.5 0.25 33 (1) 6.35 C1 0.6 B A 7.95 (t = 0.4) 3.4 19 1 13.5 10 LABEL 5.5 1.65 6 A: DETAIL (t = 0.8) B: DETAIL Aug.1999 MITSUBISHI INTELLIGNET POWER MODULES PM50CTK060 FLAT-BASE TYPE INSULATED PACKAGE EQUIVALENT CIRCUIT DIAGRAM WP VWP1 VP VVP1 UP VUP1 VWPC NC VVPC NC VUPC NC 9 11 10 12 576 8 132 4 FO NC 19 15 Rfo VNC WN 13 18 VN1 14 VN 17 UN 16 GND In FO VCC TEMP GND Si Out Th GND In FO VCC GND In FO VCC GND In VCC GND In VCC GND In VCC GND Si Out GND Si Out GND Si Out GND Si Out GND Si Out 21 NC 22 N 25 W 24 V 23 U 20 P MAXIMUM RATINGS (Tj = 25C, unless otherwise noted) INVERTER PART Symbol VCES IC ICP PC Tj Parameter Collector-emitter voltage Collector current Collector current (peak) Collector dissipation Junction temperature Conditions VD = 15V, ICIN = 10mA TC = 25C TC = 25C TC = 25C Ratings 600 50 100 100 -20 ~ +150 Unit V A A W C CONTROL PART Symbol VD ICIN VFO IFO Parameter Supply voltage Input current Fault output supply voltage Fault output current Conditions Applied between : VUP1-VUPC, VVP1-VVPC VWP1-VWPC, VN1-VNC Applied between : UP-VUPC, VP-VVPC, WP-VWPC, UN * VN * WN-VNC Applied between : FO-VNC Sink current of FO terminal Ratings 20 20 20 20 Unit V mA V mA Aug.1999 MITSUBISHI INTELLIGNET POWER MODULES PM50CTK060 FLAT-BASE TYPE INSULATED PACKAGE TOTAL SYSTEM Parameter Supply voltage protected VCC(PROT) by OC & SC VCC Supply voltage VCC(surge) Supply voltage (surge) TC Module case operating temperature Tstg Storage temperature Viso Isolation voltage Note 1 : TC measuring point is as shown below. Symbol Conditions VD = 13.5 ~ 16.5V, Inverter part, Tj = 125C start Applied between : P-N, operating time Applied between : P-N, surge and non-operating time (Note 1) 60Hz, sinusoidal, AC * 1 min Ratings 400 450 500 -20 ~ +100 -40 ~ +125 2500 Unit V V V C C Vrms TC ELECTRICAL CHARACTERISTICS INVERTER PART Symbol VCE(sat) VEC ton trr tc(on) toff tc(off) ICES Parameter Collector-emitter saturation voltage FWDi forward voltage (Tj = 25C, unless otherwise noted) Test conditions VD = 15V, ICIN = 10mA IC = 50A, Tj = 25C IC = 50A, Tj = 125C -IC = 50A, VD = 15V, ICIN = 0mA Switching time VD = 15V, ICIN = 0mA10mA VCC = 300V, IC = 50A Tj = 125C (Per 1 arm) Inductive Load VCE = VCES, ICIN = 0mA Tj = 25C Tj = 125C Collector-emitter cutoff current Min. -- -- -- 0.6 -- -- -- -- -- -- Limits Typ. 1.8 1.85 2.2 1.2 0.15 0.5 2.8 0.6 -- -- Max. 2.7 2.78 3.3 2.4 0.3 1.1 3.6 1.2 1 10 Unit V V s s s s s mA CONTROL PART Symbol ID Ith(ON) Ith(OFF) OC SC toff(OC) OT OTr UV UVr IFO(H) IFO(L) tFO Note 2 : Fault Fault Fault Fault Parameter Circuit current Input on threshold current Input off threshold current Over current trip level Short circuit trip level Over current delay time Over temperature protection Supply circuit under voltage protection Fault output current Test conditions VN1-VNC VXP1-VXPC Applied between : UP-VUPC, VP-VVPC, WP-VWPC UN * VN * WN-VNC -20C Tj 125C, VD = 15V -20C Tj 125C, VD = 15V VD = 15V Base-plate Trip level Temperature detection, VD = 15V Reset level Trip level -20C Tj 125C Reset level VD = 15V, ICIN = 0mA (Note 2) VD = 15V, VFO = 15V VD = 15V Min. -- -- 1 1 65 -- -- 100 -- 11.5 -- -- -- 1.0 Limits Typ. 40 13 3 3 88 132 10 110 90 12.0 12.5 -- 10 1.8 Max. 55 18 5 5 -- -- -- 120 -- 12.5 -- 0.01 15 -- Unit mA mA mA A A s C C V V mA mA ms Minimum fault output pulse width (Note 2) output output output output is given only when the internal OC, SC, OT & UV protection. of OC, SC protection operate by lower arm. of OC, SC protection given pulse. of OT, UV protection given pulse while over level. (OT is only N side) Aug.1999 MITSUBISHI INTELLIGNET POWER MODULES PM50CTK060 FLAT-BASE TYPE INSULATED PACKAGE THERMAL RESISTANCES Symbol Rth(j-c)Q Rth(j-c)F Rth(c-f) Parameter Junction to case thermal resistances Contact thermal resistance Test conditions Inverter IGBT part, per 1/6 module Inverter FWDi part, per 1/6 module Case to fin, thermal grease applied, per 1/6 module Min. -- -- -- Limits Tye. -- -- -- Max. 1.25 3.0 0.23 Unit C / W C / W C / W MECHANICAL RATINGS AND CHARACTERISTICS Symbol -- -- Parameter Mounting torque Weight Test conditions Mounting screw : M4 Min. 0.98 10 -- Limits Tye. 1.18 12 150 Max. 1.47 15 -- Unit N*m kg*cm g RECOMMENDED CONDITIONS FOR USE Symbol VCC VD ICIN(ON) ICIN(OFF) fPWM tdead Input on current Input off current PWM input frequency Arm shoot-through blocking time Parameter Supply voltage Test conditions Applied between : P-N Applied between : VUP1-VUPC, VVP1-VVPC VWP1-VWPC, VN1-VNC Applied between : UP, VP, WP, UN, VN, WN Using application circuit Opto-coupler's input signal Using application circuit Opto-coupler's input signal Ratings 400 (Note 3) 15 1.5 5 1 8 3 Unit V V mA mA kHz s Note 3 : Permissible ripple value : dv/dt 5V/s, Vripple 2VP-P Aug.1999 MITSUBISHI INTELLIGNET POWER MODULES PM50CTK060 FLAT-BASE TYPE INSULATED PACKAGE PERFORMANCE CURVES OUTPUT CHARACTERISTICS (TYPICAL) 60 COLLECTOR CURRENT IC (A) 50 40 30 20 10 0 COLLECTOR-EMITTER SATURATION VOLTAGE VCE (sat) (V) Tj = 25C ICIN = 10mA VD = 17V 15V 13V 2.0 VD = 15V ICIN = 10mA COLLECTOR-EMITTER SATURATION VOLTAGE CHARACTERISTICS (TYPICAL) 1.0 Tj = 25C Tj = 125C 0 10 20 30 40 50 0 0.5 1.0 1.5 2.0 2.5 3.0 COLLECTOR-EMITTER VOLTAGE VCE (V) COLLECTOR CURRENT IC (A) COLLECTOR-EMITTER SATURATION VOLTAGE VS. SUPPLY VOLTAGE (TYPICAL) COLLECTOR-EMITTER SATURATION VOLTAGE VCE (sat) (V) 2.2 101 SWITCHING TIME VS. COLLECTOR CURRENT (TYPICAL) 7 VCC = 300V 5 4 VD = 15V 3 INDUCTIVE LOAD 2 Tj = 125C SWITCHING TIMES (s) 1.8 toff ton tc(off) tc(on) 1.4 100 7 5 4 3 2 1.0 IC = 50A ICIN = 10mA Tj = 25C Tj = 125C 12 14 16 18 20 0.6 0.2 10-1 0 10 2 3 4 5 7 101 2 3 4 5 7 102 SUPPLY VOLTAGE VD (V) COLLECTOR CURRENT IC (A) IC (A) FREE-WHEEL DIODE FORWARD CHARACTERISTICS (TYPICAL) 102 7 5 4 3 2 COLLECTOR REVERSE CURRENT VD = 15V ICIN = 0mA Tj = 25C Tj = 125C 2 2 101 7 5 4 3 2 10-1 7 5 4 3 2 trr 101 7 5 4 3 2 3 4 5 7 101 3 4 5 7 102 100 0 0.5 1.0 1.5 2.0 2.5 10-2 0 10 100 2 2 EMITTER-COLLECTOR VOLTAGE VEC (V) COLLECTOR REVERSE CURRENT IC (A) Aug.1999 REVERSE RECOVERY CURRENT Irr (A) REVERSE RECOVERY TIME trr (s) REVERSE RECOVERY CHARACTERISTICS OF FREE-WHEEL DIODE (TYPICAL) 102 100 Tj = 125C 7 7 VCC = 300V 5 5 4 4 VD = 15V INDUCTIVE LOAD Irr 3 3 MITSUBISHI INTELLIGNET POWER MODULES PM50CTK060 FLAT-BASE TYPE INSULATED PACKAGE TRANSIENT THERMAL IMPEDANCE CHARACTERISTICS (IGBT per 1 element) 101 TRANSIENT THERMAL IMPEDANCE CHARACTERISTICS (FWDi per 1 element) 101 NORMALIZED TRANSIENT THERMAL IMPEDANCE Zth (j - c) 100 7 5 3 2 7 5 3 2 7 5 3 2 NORMALIZED TRANSIENT THERMAL IMPEDANCE Zth (j - c) 7 Single Pulse 5 3 Rth(j - c)Q = 1.25C/ W 2 7 Single Pulse 5 3 Rth(j - c)F = 3.0C/ W 2 7 5 3 2 7 5 3 2 7 5 3 2 100 10-1 10-1 10-2 10-2 10-3 10-3 2 3 5 710-2 2 3 5 710-1 2 3 5 7100 2 3 5 7101 TIME (s) 10-3 10-3 2 3 5 710-2 2 3 5 710-1 2 3 5 7100 2 3 5 7101 TIME (s) Aug.1999 |
Price & Availability of PM50CTK060 |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |